Type: | Wired |
---|---|
Network Site: | Enterprise Router |
Transfer Rate: | 1000Mbps |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
NetEngine 8000 F1A-8H20Q Access Aggregation Router for the Cloud Era
Basic Information | |
Part Number | 02353AES |
Model | NetEngine 8000 F1A-8H20Q |
Description | NetEngine 8000 F1A-8H20Q Integrated Chassis Components (Port-side Intake) |
First supported version | V800R012C00SPC300 |
Technical Specifications | |
Height [mm] | 43.6 mm |
Depth [mm] | 420 mm |
Wide [mm] | 442 mm |
Chassis height [U] | 1 U |
Weight without packaging (full configuration) [kg(lb)] | DC: 8.4 kg(18.52 lb) AC: 8.75 kg(19.29 lb) |
Weight without packaging [kg(lb)] | 6.3 kg (13.89 lb) |
Weight with packaging (full configuration) [kg(lb)] | DC: 13.58 kg(29.94 lb) AC: 13.75 kg(30.31 lb) |
Weight with packaging [kg(lb)] | 11.2 kg (24.69 lb) |
Typical power consumption (with configuration) [W] | 325 W |
Maximum power consumption (with configuration) [W] | 420 W |
Typical heat dissipation (with configuration) [BTU/hour] | 1054.44 BTU/hour |
Heat dissipation mode | Air cooling |
Maximum heat dissipation (with configuration) [BTU/hour] | 1362.66 BTU/hour |
Power supply mode | DC,AC/HVDC |
Rated input voltage [V] | DC: -48 V/-60 V AC: 100 V to 240 V AC, support 240 V HVDC |
Input voltage range [V] | DC: -40 V to -72 V AC: 90 V to 290 V |
Maximum input current [A] | DC: 30 A 600 W AC: 8 A 1200 W AC: 10 A |
Rated output power [W] | DC: 1000 W 600 W AC: 600 W 1200 W AC: 1200 W |
Number of slots | 7 |
Number of service board slots | 1 |
CPU | 20-core 2.0 GHz |
SDRAM | 16 GB |
Storage | 4G NAND FLASH |
Flash memory | 64 MB |
Switching capacity [bps,bit/s] | 2.4 Tbit/s |
Redundant fans | 3+1, normal operation at 40°C (104°F) for a short term after a fan fails |
Redundant power supply | 1+1 |
Noise at normal temperature (acoustic power) [dB(A)] | < 72 dB (meeting the ETSI 72 dBA standard) |
Airflow direction | Front to back: port-side intake |
Maximum input cable size | DC: 4 mm² (1 m to 14 m), 6 mm² (15 m to 21 m), 10 mm² (22 m to 35 m) AC: 2.5 mm² |
Front-end circuit breaker/fuse | DC:≥32A AC:≥10A |
Long-term operating temperature [°C(°F)] | Front-to-rear model: -5°C to +45°C (23°F to 113°F) |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158 °F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 0.5°C/min (32.9°F/min), non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating relative humidity [RH] | 5% RH to 90% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage altitude [m(ft.)] | < 5000 m (16404.2 ft.) |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
MTBF [year] | DC: 25.52 AC: 25.65 |
MTTR [hour] | 0.5 |
Availability | 0.99999 |
Breakout supported | Yes. Only 100GE interfaces support interface breakout. To enable interface breakout, run the port split command. |
Interface rate auto-sensing supported | Yes 0-27: 10GE ports, supporting 10GE/GE auto-sensing; 28-35: 25GE ports, supporting 25GE/10GE auto-sensing in 25GE mode and 10GE/GE auto-sensing in 10GE auto-sensing mode; 36-47: 25GE ports, supporting 25GE/10GE auto-sensing; 48-55: 100GE ports, supporting 40GE/50GE/100GE auto-sensing. |
Maximum number of 10GE ports | 80 (0 to 47: 48 10GE ports; 48 to 55: split into 32 10GE ports) |
Maximum number of FE ports | 28 |
Maximum number of physical ports on the entire device | 56 |
Maximum number of 50GE ports | 8 |
Maximum number of 25GE ports | 52 (28 to 47: 20 25GE ports; 48 to 55: split into 32 25GE ports) |
Maximum number of GE ports | 36 (V800R012C00: 28, V800R012C10 and later versions: 36) |
Maximum number of electrical ports | 28 |
Maximum number of 100GE ports | 8 |
Maximum number of 40GE ports | 8 |