Communication Mode: | Full-Duplex & Half-Duplex |
---|---|
Type: | Network Switch |
Transmission Rate: | 10/100/1000Mbps |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
8-port Gigabit POE Network Switch S5735-L8T4X-QA-V2 Switch
Basic Information | |
Part Number | 98012073 |
Model | S5735-L8T4X-QA-V2 |
Description | S5735-L8T4X-QA-V2 (8*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power, Fanless) |
Technical Specifications | |
Chassis material | Metal |
Height [mm] | 43.6 mm |
Depth [mm] | 180.0 mm |
Wide [mm] | 250.0 mm |
Chassis height [U] | 1 |
Weight with packaging [kg(lb)] | 2.21 (4.87) |
Weight without packaging [kg(lb)] | 1.40 kg (3.09 lb) |
Maximum power consumption [W] | 16.97 |
Typical power consumption [W] | 16.2 |
Heat dissipation mode | Natural heat dissipation |
Maximum heat dissipation [BTU/hour] | 57.9 |
Typical heat dissipation [BTU/hour] | 55.28 |
Power supply mode | AC built-in |
Input voltage range [V] | AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz |
Rated input voltage [V] | AC input: 100 V AC to 240 V AC, 50/60 Hz |
Maximum input current [A] | 0.8 A |
Number of power slots | 0 |
Number of card slots | 0 |
Memory | 2 GB |
Flash memory | Physical space: 1 GB |
Redundant power supply | Not supported |
Types of fans | None |
Noise at normal temperature (acoustic power) [dB(A)] | Noise-free (no fans) |
Noise at normal temperature (acoustic pressure) [dB(A)] | Noise-free (no fans) |
Airflow direction | - |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
MTBF [year] | 76.15 |
MTTR [hour] | 2 |
Availability | > 0.99999 |
Maximum number of physical ports on the entire device | 12 |
Maximum number of 100GE ports | 0 |
Maximum number of 40GE ports | 0 |
Maximum number of 25GE ports | 0 |
Maximum number of 10GE ports | 4 |
Maximum number of GE ports | 12 |
Maximum number of FE ports | 8 |
10GE optical interface | 4 |
1000M electrical interface | 8 |
USB | Not supported |
Console port | RJ45 |
Eth Management port | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection | ±6 kV in differential mode, ±6 kV in common mode |
RPS input | Not supported |
PoE | Not supported |